Part number

CX 25 IF

Brief description: female insert, 25 poles, crimp connections, 4A 50V, 3, for 5A female contacts, 1 module, modular units series MIXO

CX 25 IF

Technical details

Product description
Model female insert
Version Crimp connection
Product type for 5A female contacts
Family MIXO series, customizable inserts
Size 1 module
N. of poles 25 poles
Technical data
Current 4 A
Voltage 50  V
Pollution degree 3
Operating temperature range (min, max) -40°C … +125°C
IP degree of protection IP20 without enclosure, IP65/IP66/IP68/IP69 with enclosure
Further technical details
Characteristics according to EN 61984 5A 50V 10A 3
Insulation resistance ≥ 10 GΩ
Contact resistance ≤ 4 mΩ
Rated voltage according to UL/CSA 600 V
UL 94 flammability rating V-0
Weight 9,00 g
Approvals / Standards
Reference standard EN 61984:2009-06
Quality mark , DNV GL, BV
Conformity Not applicable
General ordering information
EAN13 code 8015747148313
Tariff number
Packaging Information
Packaging length 180,00 mm
Packaging height 130,00 mm
Packaging width 150,00 mm
Packaging weight 2,00 kg
Packaging volume 3,51 dm³
Packaging description Carton box
Packaging quantity 60 Pcs
Packaging EAN code 8015747221351
Sub-packaging length 35,00 mm
Sub-packaging height 40,00 mm
Sub-packaging width 155,00 mm
Sub-packaging weight 0,33 kg
Sub-packaging volume 0,22 dm³
Sub-packaging description Carton tray
Sub-packaging quantity 10 Pcs
Sub-packaging EAN barcode 8015747148337

Notes

Inserts CX 25 IF/M

- characteristics according to EN 61984:
4A 50V 0.8kV 3
4A 160V 2.5kV 2
- insulation resistance: > 10 GOhm
- ambient temperature limit: -40 °C ... +125 °C
- are made of self-extinguishing thermoplastic resin
UL 94 V0
- mechanical life: > 500 cycles
- for crimp contacts CI series using:
CIPZ D crimping tool
CITP D turret head
CIES insertion / removal tool
- we recommend the use of CRF / CRM code pins
- 1 frame slot


the modular inserts must be installed in suitable frames which in turn are installed in traditional housings or COB panel support